Czech J. Anim. Sci., 2008, 53(2):83-89 | DOI: 10.17221/329-CJAS

Effect of microclimate on the airborne dust and endotoxin concentration in a broiler house

M. Vučemilo1, K. Matković1, B. Vinković2, J. Macan3, V.M. Varnai3, Lj. Prester3, K. Granić4, T. Orct3
1 Department of Animal Hygiene, Environment and Ethology, School of Veterinary Medicine, University of Zagreb, Zagreb, Croatia
2 Department of Zoohygiene and Livestock Technology, Croatian Veterinary Institute, Zagreb, Croatia
3 Institute of Medical Research and Occupational Health, Zagreb, Croatia
4 ZIN-LAB Laboratory for Foodstuffs of Animal Origin, Veterinary Station of Zagreb City, Zagreb, Croatia

Poultry farming is considered to be a notable source of bioaerosols. They can be a risk factor from the aspect of some diseases and for the environment. A study was conducted to assess the effect of microclimate on the level of airborne dust and endotoxins in an intensive broiler fattening facility. The content of airborne dust, endotoxins, air temperature, relative humidity, airflow velocity, ammonia and carbon dioxide were determined. The study was conducted in a poultry house accommodating 22 000 broilers of Ross-308 breed. The measured temperature in the broiler house ranged from 22.02°C to 31.05°C, relative humidity from 49.55% to 65.45%, and airflow velocity from 0.07 m/s to 0.09 m/s. The air concentration of dust ranged from 2.0 mg/m3 at the end of fattening period to 4.9 mg/m3 in the mid-fattening period, and endotoxins from 6.21 EU/m3 in the second study week to 99.40 EU/m3 at the end of fattening period. The air concentration of ammonia ranged from 5.17 ppm at the beginning to 25.49 ppm at the end of fattening period. Air concentrations of dust and endotoxins recorded in this poultry house varied during the fattening period and depended on relative humidity and temperature as demonstrated by multiple regression at the level of P ≤ 0.05.

Keywords: broilers; dust; endotoxins; ammonia; carbon dioxide

Published: February 29, 2008  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Vučemilo M, Matković K, Vinković B, Macan J, Varnai VM, Prester L, et al.. Effect of microclimate on the airborne dust and endotoxin concentration in a broiler house. Czech J. Anim. Sci. 2008;53(2):83-89. doi: 10.17221/329-CJAS.
Download citation

References

  1. Anonymous (1987): Guideline on validation of the limulus amebocyte lysate test as an end-product endotoxin test for human and animal parenteral drugs, biological products and medical devices. US Food and Drug Administration, US Department of Health and Human Services, US Public Health Service.
  2. Anonymous (1994): Statistica. Quick Reference. StatSoft, Inc., Tulsa, USA.
  3. Anonymous (1998): Dutch Expert Committee on Occupational Standards. Endotoxins: health based recommended exposure limit. A report of the Health Council of the Netherland, publication No. 1998/03WGD. Health Council of the Netherlands, Rijkswijk.
  4. Clark S., Rylander R., Larsson L. (1983): Airborne bacteria, endotoxin and fungi in dust in poultry and swine confinement buildings. Am. Ind. Hyg. Assoc. J., 44, 537-541. Go to original source... Go to PubMed...
  5. Donham K.J. (1995): The effects of environmental conditions inside swine housing on worker and pig health, a review. In: Hennessey D.P., Cranwell P.D. (eds.): Manipulating Pig Production V., Werribee. Australasian Pig Science Association, Victorian Institute of Animal Science, Victoria, Australia, 203-221.
  6. Hauser R.H., Folsch D.W. (1993): The quality of poultryhouse air in alternative systems for farming laying hens. In: Collins E., Boon C. (eds.): Livestock Environment IV. American Society of Agricultural Engineers, Michigan, USA, 671-677.
  7. Hristov S. (2002): Zoohigijena. Univerzitet u Beogradu. Poljoprivredni fakultet. Zemun.
  8. Hyvärinen A., Roponen M., Tiittanen P., Laitinen S., Nevalainen A., Pekkanen J. (2006): Dust sampling methods for endotoxin - an essential, but underestimated issue. Indoor Air, 16, 20-27. Go to original source... Go to PubMed...
  9. Jacobs R.R., Heederik D., Douwes J., Zähringer U. (1997): Endotoxin structure. Int. J. Occup. Environ. Med., 3, S6-S7.
  10. Lacey J. (1994): Microorganisms in organic dust. In: Rylander R., Jacobs R.R. (eds.): Organic Dusts: Exposure, Effects and Prevention. Lewis Publishers, London, UK, 17-41. Go to original source...
  11. Liebers V., Bruning T., Raulf-Heimsoth M. (2006): Occupational endotoxin-exposure and possible health effects on humans. Am. J. Ind. Med., 49, 474-491. Go to original source... Go to PubMed...
  12. Madsen A.M. (2006): Airborne endotoxins in different background environments and seasons. Ann. Agric. Environ. Med., 13, 81-86.
  13. Müller W., Weiser P. (1987): Dust and microbial emissions from animal production. The influence of dust and airborne bacteria on the health of man and livestock. In: Strauch D. (ed.): Animal Production and Environmental Health. Elsevier, Amsterdam, Oxford, New York, Tokyo, 81-84.
  14. Olenchock S.A. (1988): Endotoxins in various work environments in agriculture. Dev. Ind. Microbiol., 31, 193-197.
  15. Petz B. (2001): Osnovne statističke metode za nematematičare. 4th ed. Naklada Slap, Jastrebarsko. Croatia.
  16. Pickrell J.A., Herber A.J., Murphy J.P., Henry S.C., May M.M., Nolan D., Oehme F.W., Gillespie J.R., Schoneweis D. (1993): Characterization of particles, ammonia and endotoxin in swine confinement operations. Vet. Hum. Toxicol., 35, 421-428.
  17. Radon K., Danuser B., Martin I., Monso E., Cristoph W., Hartung J., Donham K.J., Palmgren U., Nowak D. (2002): Air contaminants in different European farming environments. Ann. Agric. Environ. Med., 9, 41-48.
  18. Rylander R. (2002): Endotoxin in the environment - exposure and effects. J. Endotoxin Res., 8, 241-252. Go to original source... Go to PubMed...
  19. Rylander R. (2006): Endotoxin and occupational airway disease. Curr. Opin. Allergy Clin. Immunol., 6, 62-66. Go to original source... Go to PubMed...
  20. Seedorf J. (2004): An emission inventory of livestockrelated bioaerosols for Lower Saxony, Germany. Atmos. Environ., 38, 6565-6581. Go to original source...
  21. Seedorf J., Hartung J., Schröder M., Linkert K.H., Phillips V.R., Holden M.R., Sneath R.W., Short J.L., White R. P., Pedersen S. (1998): Concentrations and emissions of airborne endotoxins and microorganisms in livestock buildings in Northern Europe. J. Agr. Eng. Res., 70, 97-109. Go to original source...
  22. Siegmann O., Neumann U. (2005): Haltung. In: Siegmann O., Neumann U. (eds.): Kompendium der Geflügelkrankheiten. Schlütersche Verlagsgesekkschaft, Hannover, Germany, 48-62.
  23. Takai H., Pedersen S., Johnsen J.O., Metz J.H.M., Groot Koerkamp P.W.G., Uenk G.H., Phillips V.R., Holden M.R., Sneath R.W., Short J.L., White R.P., Hartung J., Seedorf J., Schröder M., Linkert K.H., Wathes C.M. (1998): Concentrations and emissions of airborne dust in livestock buildings in Northern Europe. J. Agr. Eng. Res., 70, 59-77. Go to original source...
  24. Thedell T.D., Mull J.C., Gladish M.E., Peach M.J. (1980): A brief report of gram-negative bacteria endotoxin levels in airborne and settled dust in animal confinement buildings. Am. J. Ind. Med., 1, 3 pp. Go to original source... Go to PubMed...
  25. Varnai M.V., Macan J., Plavec D., Jureša D. (2004): Endotoxin measurement in house dust using the end-point limulus amebocyte lysate method. Arh. Hig. Rada Toksikol., 55, 175-181. Go to PubMed...
  26. Vučemilo M., Vinković B., Tofant A., Šimpraga B., Pavičić Ž., Matković K. (2005): Microbiological air contamination in intensive poultry breeding. In: Proc. 7 th Int. Congr. ISAH 2005, 4-8 September, Warsaw, Poland, 1, 127-129.
  27. Vučemilo M., Matković K., Vinković B., Jakšić S., Granić K., Mas N. (2007): The effect of animal age on air pollutant concentration in a broiler house. Czech J. Anim. Sci., 52, 170-174. Go to original source...
  28. Wathes C.M. (1994): Air and surface hygiene. In: Wathers C.M., Charles D.R. (eds.): Livestock Housing. CAB International, Wallingford, UK, 123-148.
  29. Wathes C.M., Holden M.R., Sneath R.W., White R.P., Phillips V.R. (1997): Concentrations and emission rates of aerial ammonia, nitrous - oxide, carbon dioxide, dust and endotoxin in UK broiler and layer houses. Brit. Poult. Sci. 38, 14-28. Go to original source... Go to PubMed...
  30. Wathes C.M., Phillips V.R., Holden M.R., Sneath R.W., Short J.L., White R.P., Hartung J., Seedorf J., Schröder M., Linkert K.H., Pedersen S., Takai H., Johnsen J.O., Groot Koerkamp P.W.G., Uenk G.H., Metz J.H.M., Hinz T., Caspary V., Linke S. (1998): Emissions of aerial pollutants in livestock buildings in Northern Europe. Overview of a multinational project. J. Agr. Eng. Res., 70, 3-9. Go to original source...
  31. Whyte R.T., Williamson P.A.M., Lacey J. (1993): Air pollutant burdens and respiratory impairment of poultry house stockmen. In: Livestock Environment IV. 4th Int. Symp., University of Warwick, Coventry, ASAE, St. Joseph, MI, UK, 709-717.

This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International (CC BY NC 4.0), which permits non-comercial use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.