Simple, selective, and sensitive measurement of urea in body fluids of mammals by reversed-phase ultra-fast liquid chromatography
- The Kielanowski Institute of Animal Physiology and Nutrition, Polish Academy of Sciences, Jabłonna, Poland
Ultra-fast liquid chromatography with a photodiode array detector for simple and rapid determination of urea in body fluids of farm animals is described. Blood plasma, milk, and urine samples are treated with trichloroacetic acid and then centrifuged. Supernatants are derivatized at room temperature using p-dimethylaminobenzaldehyde. Samples are separated using a ternary gradient of methanol in buffer and water. Derivatized urea in standards and biological samples is analyzed using a Phenomenex C18-column (Synergi 2.5 µm, Hydro-RP, 100Å, 100 × 2 mm). The photodiode detector is set to 370 and/or 254 nm for detection. Temperature is maintained at 27°C by a column heater. Clear separation of derivatized urea from the endogenous species present in assayed biological samples was achieved in less than 6 min. The urea adduct peak eluted at 4.36 ± 0.05 min. Average recoveries of the urea standards added to assayed biological materials were satisfactory (i.e. 100.2 ± 4.1%). Our chromatographic method with photodiode detection at 370 nm and at 254 nm, in particular, offers low detection (LD) and quantification limits (LQ) (370nmLD = 0.47 ng, 254nmLD = 0.027 ng and 370nmLQ = 1.41 ng, 254nmLQ = 0.080 ng, respectively). Our liquid chromato-graphy based on detection at 370 nm is the most versatile analytical tool that assures sensitive, accurate, and precise analysis of urea in urine, milk, and plasma samples, and selected diets for mammals. The presented chromatographic procedure is especially suitable for preparation of reference sample sets, very accurate and precise research purposes or rapid clinical diagnostic with smaller sample sets. Urea in urine can be also determined using our liquid chromatography with detection at 254 nm. Detection of urine urea at 254 nm is more sensitive and precise compared with monitoring at 370 nm. Our chromatographic method based on photodiode detection at 370 nm and especially at 254 nm is suitable for the non-invasive analysis of urea in only urine of humans and animals.
Keywords: Keywords: urea; derivatization; liquid chromatography; milk; blood plasma; urine
Published: January 31, 2012 Show citation
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
References
- Carlsson J., Bergström J. (1994): The diurnal variation of urea in cow's milk and how milk fat content, storage and preservation affects analysis by a flow injection technique. Acta Veterinaria Scandinavica, 35, 67-77.
Go to original source...
Go to PubMed...
- Clark S., Francis P.S., Conlan X.A., Barnett N.W. (2007): Determination of urea using high-performance liquid chromatography with fluorescence detection after automated derivatisation with xanthydrol. Journal of Chromatography A, 1161, 207-213.
Go to original source...
Go to PubMed...
- Czauderna M., Kowalczyk J. (2001): Separation of some mono-, di- and tri-unsaturated fatty acids containing 18 carbon atoms by high-performance liquid chromatography and photodiode array detection. Journal of Chromatography B, 760, 165-178.
Go to original source...
Go to PubMed...
- Czauderna M., Kowalczyk J. (2009): Easy and accurate determination of urea in milk, blood plasma, urine and selected diets of mammals by high-performance liquid chromatography with photodiode array detection preceded by pre-column derivatization. Chemical Analysis, 54, 919-937.
- Dallet Ph., Labat L., Kummer E., Dubost J.P. (2000): Determination of urea, allantoin and lysine pyroglutamate in cosmetic samples by hydrophilic interaction chromatography. Journal of Chromatography B, 742, 447-452.
Go to original source...
Go to PubMed...
- Dhawan G., Sumana G., Malhotra B.D. (2009): Recent developments in urea biosensors. Review. Biochemical Engineering Journal, 44, 42-52.
Go to original source...
- Ferguson J.D. (2000): Milk Urea Nitrogen. Center for Animal Health and Productivity, Pennsylvania, USA.
- Francis P.S., Lewis S.W., Lim K.F. (2002): Analytical methodology for the determination of urea: current practice and future trends. Trends in Analytical Chemistry, 21, 5, 389-400.
Go to original source...
- Gutiérrez M., Alegret S., del Valle M. (2008): Bioelectronic tongue for the simultaneous determination of urea, creatinine and alkaline ions in clinical samples. Biosensors and Bioelectronics, 23, 795-802.
Go to original source...
Go to PubMed...
- Hanuš O., Hering P., Frelich J., Jilek M., Genčurova V., Jedelska R. (2008): Reliability of results of milk urea analysis by various methods using artificial milk control samples. Czech Journal of Animal Science, 53, 152-161.
Go to original source...
- Hering P., Hanuš O., Frelich J., Pytloun J., Macek A., Janů L., Kopecký J. (2008): Relationships between the results of various methods of urea analysis in native and enriched milk. Czech Journal of Animal Science, 53, 64-76.
Go to original source...
- Jílek F., Řehák D., Volek J., Štípková M., Němcová E., Fiedlerová M., Rajmon R., Švestková D. (2006): Effect of herd, parity, stage of lactation and milk yield on urea concentration in milk. Czech Journal of Animal Science, 51, 510-517.
Go to original source...
- Lin J.T., McKeon T.A. (2005): HPLC of Acyl Lipids. HNB Publishing, New York, USA.
- Oltner R., Bengtsson S., Larson K. (1985): Flow injection analysis for the determination of urea in cows milk. Acta Veterinaria Scandinavica, 26, 396-404.
Go to original source...
Go to PubMed...
- Petersom A.B., French K.R., Russek-Cohen E., Kohn R.A. (2004): Comparison of analytical methods and the influence of milk components on milk urea nitrogen recovery. Journal of Dairy Science, 87, 1747-1750.
Go to original source...
Go to PubMed...
- Řehák D., Rajmon R., Kubešová M., Štípková M., Volek J., Jílek F. (2009): Relationships between milk urea and production and fertility traits in Holstein dairy herds in the Czech Republic. Czech Journal of Animal Science, 54, 193-200.
Go to original source...
- Sehitoğullari A., Uslan A.H. (2002): Preparation of a potentiometric immobilized urease electrode and urea determination in serum. Talanta, 57, 1039-1044.
Go to original source...
Go to PubMed...
- Sejrsen K., Hvelplund T., Nielsen M.O. (2006): Ruminant Physiology. Wageningen Academic Publishers, Wageningen, the Netherlands.
Go to original source...
- Sheppard N.F., Mears D.J., Guiseppi-Elie A. (1996): Model of an immobilized enzyme conductimetric urea biosensor. Biosensors and Bioelectronics, 11, 967-979.
Go to original source...
- Yatzidis H., Garidi M., Vassilikos C., Mayopoulou D., Akilas A. (1964): An improved method for the simple and accurate colometric determination of urea with Ehrlich's reagent. Journal of Clinical Pathology, 17, 163-164.
Go to original source...
Go to PubMed...
- Zhai S.W., Liu J.X., Wu Y.M., Ye J.A., Xu Y.N. (2006): Responses of milk urea nitrogen content to dietary crude protein level and degradability in lactating Holstein dairy cows. Czech Journal of Animal Science, 51, 518-522.
Go to original source...
This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International (CC BY NC 4.0), which permits non-comercial use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.